FIWE Fiber AnalyzersDownloads

FIWE Fiber AnalyzersDownloads

Description

Crude Fiber, Neutral & Acid Detergent Fiber

FIWE 3 and FIWE 6 are fiber analyzers suitable for raw fiber extraction, conventionally known as an indigestible residue. Rapid analysis, reliable results and high reproducibility are some of the most relevant benefits of these units which are ideal for the following applications:

- The Weende method, the oldest analytical procedure still in use today, in which fiber concentration is measuredas crude fiber (CF)

- The Neutral Detergent Fiber (NDF), a method developed by Van Soest, now the most common measure of fiberused for animal feed analysis

- Acid Detergent Fiber (ADF), a portion of the plant fiber and includes cellulose, lignin and variable amountsof xylans.

- Acid Detergent Lignin (ADL) determination and Wijkstrom technique, a modification of the Weende method


High Reliability, Single or Multiple Extractions:

Perform single or multiple extractions including boiling, rinsing and filtration steps with the maximum reproducibility available.

No sample transfer prevents any possible sample loss, as crucibles can also be used as sample vessels during weighing, drying and washing.

Pre-heat the reagents with RC2 hot plate (included), and pour them directly into the system.


Rapid Heating Element:

An extremely efficient heating element speeds up the analysis, ensuring rapid heating of the sample, previously mixed with pre-heated reagents.

Also after the second reagent addition, the heating element grants a fast re-heating of the solution, for conspicuous saving in terms of time.

In fact, FIWE Series reduces the time required for the analysis: the equivalent manual procedure will require more than 6 hours, compared to the 2 hours with FIWE.
No transfer and sample loss:

In order to prepare the sample for fiber analysis, COEX ensures rapid fat extraction directly into the same glass crucibles used by the FIWE series.

The crucible, containing the defatted sample, is transferred directly to the FIWE analyzer, eliminating possible errors due to sample transfer.

Downloads

Specifications

ManufacturerVelp Scientifica
CONSTRUCTION MATERIALepoxy painted stainless steel structure
TYPE OF EXTRACTIONScold and hot extractions
NUMBER OF SAMPLESFIWE 33 positionsFIWE 66 positions
SAMPLESindividually processed
SAMPLE QUANTITYfrom 0,5 to 3 g
REPRODUCIBILITY (RSD)± 1%
SAMPLE REMOVALair pump
REAGENT DISCHARGEperistaltic pump
DIGITAL TIMER0 - 99 minutes with acoustic signal at the end
TEMPERATUREelectronic regulation
REAGENTS AND COOLING WATERseparated outlets
POWERFIWE 3900 WFIWE 61200 W
WEIGHTFIWE 335 Kg (77 lb)FIWE 640 Kg (101.2 lb)
DIMENSIONS (WXHXD)FIWE 3530x620x390 mm (20.9x24.4x15.4 in)FIWE 6760x620x390 mm (29.5x24.4x15.4 in)
APPLICATIONSRaw fiber (Weende, Wijstrom)Neutral or acid detergent treatment fiber (Van Soest)Lignin, Cellulose, Hemicellulose